REGI / DTF FUME & OIL PURIFICATION
DTF Fume Purifier
Systems for Production Lines.
Compare four DTF printer fume-extractor and purifier airflow options from 290 to 2000m³/h. Configurations are listed for dual-head and four-/five-head white-ink DTF production, with high-temperature aluminum hose and replaceable filter cartridges.

J25 Series · 2,000 m³/h Fume Purifier
01 / PURIFIER RANGE
Choose airflow for the printer and process.
The catalogue lists four J25 purifier configurations. Two are recommended for dual-head white-ink machines; higher-airflow units are listed for four-/five-head lines and extended ovens.

290m³/h · 230W
Compact white-ink smoke purifier listed for dual-head machines.
1 × Ø50mm inlet15.2kg net
900m³/h · 450W
Fume and oil purifier listed for double-head white-ink machines.
1 × Ø50mm inlet21kg net
1500m³/h · 450W
Dedicated white-ink smoke purifier recommended for four-/five-head machines.
1 × Ø50mm inlet30kg net
2000m³/h · 1000W
Higher-airflow smoke and oil purifier with 10-stage suction control and 1–2 inlets.
1–2 × Ø50mm inlet35kg net02 / MODEL COMPARISON
Four airflow and power configurations.
Filtration performance is shown as a supplier-catalogue claim. Request the current test report and filter documentation before using it for regulatory or workplace-compliance decisions.
| Specification | 290m³/h | 900m³/h | 1500m³/h | 2000m³/h |
|---|---|---|---|---|
| Power | 230W | 450W | 450W | 1000W |
| Air volume | 290m³/h | 900m³/h | 1500m³/h | 2000m³/h |
| Catalogue filtration claim | 0.3μm / 99.97% | 0.3μm / 99.97% | 0.3μm / 99.97% | 0.3μm / 99.97% |
| Voltage / frequency | 110V / 220V, 50/60Hz | 110V / 220V, 50/60Hz | 110V / 220V, 50/60Hz | 110V / 220V, 50/60Hz |
| Inlet | Ø50mm × 1 | Ø50mm × 1 | Ø50mm × 1 | Ø50mm × 1–2 |
| High-temperature hose | 3m | 3m | 3m | 3m |
| Wooden-case packing | 62 × 39 × 71cm | 68 × 39 × 72cm | 88 × 57 × 73cm | 61 × 58 × 102cm |
| Net / gross weight | 15.2 / 34kg | 21 / 40kg | 30 / 56.5kg | 35 / 61kg |
| Catalogue application | Dual-head white-ink machine | Dual-head white-ink machine | Four-/five-head white-ink machine | Four-/five-head line, extended oven, double outlet |
The catalogue describes a wooden case and one set of filter cartridges as included with the machine. Replacement filter sets or additional screens may be separate items. Confirm spare-filter quantity and part numbers before ordering.
03 / MODEL DETAILS
Airflow, connection and packaging references.
The catalogue uses J25 as the purifier family label across these configurations.

Equipment overview
01 / DUAL-HEAD APPLICATION
J25 compact white-ink smoke purifier — 290m³/h
The catalogue recommends this 230W purifier for double-head white-ink DTF processing. It includes one Ø50mm inlet and a 3m high-temperature aluminum tube.
| Filtration claim | 0.3μm / 99.97% |
|---|---|
| Voltage / frequency | 110V / 220V, 50/60Hz |
| Inlet / hose | Ø50mm × 1 / 3m |
| Wooden-case packing | 62 × 39 × 71cm |
| Gross weight | 34kg |
| Catalogue application | Double-head white-ink DTF processing; powder-shaker fume treatment |

Equipment overview
02 / DUAL-HEAD APPLICATION
J25 fume and oil purifier — 900m³/h
A 450W double-head configuration with adjustable suction and an oil-leak design, as described in the catalogue.
| Filtration claim | 0.3μm / 99.97% |
|---|---|
| Voltage / frequency | 110V / 220V, 50/60Hz |
| Inlet / hose | Ø50mm × 1 / 3m |
| Wooden-case packing | 68 × 39 × 72cm |
| Gross weight | 40kg |
| Catalogue application | Double-head white-ink DTF processing; adjustable suction; oil-leak design |

Equipment overview
03 / FOUR- AND FIVE-HEAD APPLICATION
J25 dedicated white-ink smoke purifier — 1500m³/h
A dedicated 450W purifier listed for four-/five-head white-ink machines, flag-machine processing and industrial oily-smoke purification.
| Filtration claim | 0.3μm / 99.97% |
|---|---|
| Voltage / frequency | 110V / 220V, 50/60Hz |
| Inlet / hose | Ø50mm × 1 / 3m |
| Wooden-case packing | 88 × 57 × 73cm |
| Gross weight | 56.5kg |
| Catalogue application | Four-/five-head white-ink machines, flag machines and oily-smoke processing |

Equipment overview
04 / HIGH-AIRFLOW APPLICATION
J25 smoke and oil purifier — 2000m³/h
The highest-airflow configuration in the referenced catalogue, with a 10-stage suction control panel and one or two inlets for the listed double-outlet application.
| Filtration claim | 0.3μm / 99.97% |
|---|---|
| Voltage / frequency | 110V / 220V, 50/60Hz |
| Inlet / hose | Ø50mm × 1–2 / 3m |
| Machine dimensions | 43 × 45 × 80cm |
| Wooden-case packing | 61 × 58 × 102cm |
| Gross weight | 61kg |
| Control / application | 10-stage suction control; single / double inlet; extended oven and four-/five-head line |
The catalogue describes indoor air recirculation without external discharge for this model. Confirm local ventilation, workplace and installation requirements before relying on this arrangement.
04 / SELECTION GUIDE
Match purifier capacity to the actual line.
Use the catalogue’s recommended machine class as a starting point, then confirm the total extraction requirement with your equipment supplier and local ventilation professional.
DUAL-HEAD LINES
290 or 900m³/h
- Compact white-ink smoke extraction: 290m³/h option.
- Higher airflow and oil-fume configuration: 900m³/h option.
- Confirm number of extraction points and hose routing.
FOUR-/FIVE-HEAD LINES
1500 or 2000m³/h
- Dedicated white-ink smoke extraction: 1500m³/h option.
- Extended oven / double-outlet application: 2000m³/h option.
- Check electrical load, duct arrangement and local exhaust rules.
The 0.3μm / 99.97% figure is reproduced from the supplier catalogue only. Request a current filter test report, replacement-filter specification and installation instructions before making compliance claims.
05 / BUYER FAQ
DTF fume purifier questions.
Which purifier is listed for a dual-head DTF printer?
The catalogue recommends the 290m³/h and 900m³/h variants for double-head white-ink machines. The final choice depends on extraction points and the actual process.
Which purifier is listed for four-/five-head machines?
The 1500m³/h dedicated smoke purifier and the 2000m³/h smoke-and-oil purifier are listed for four-/five-head production configurations.
What hose is included?
The catalogue lists a 3m high-temperature aluminum tube for all four configurations.
Is the 99.97% filtration claim independently certified?
The supplied catalogue states 0.3μm / 99.97%. Ask REGI for the current test report and filter documentation before using the figure for regulatory or workplace-compliance claims.
Can the 2000m³/h unit operate without external discharge?
The catalogue describes indoor recirculation for this model. Confirm local ventilation, occupational-safety and installation requirements before selecting this setup.
REGI / EQUIPMENT SOLUTIONS
Choose a purifier for your DTF line.
Send your printer head count, powder-shaker model, number of extraction points, voltage and destination. REGI can help match the catalogue configuration and confirm filter documentation.